The Huarui microcomputer-controlled arrester bending and tensile testing machine is primarily used to test mechanical properties of arresters, including tension, compression, and bending. Equipped with specialized arrester bending and tensile fixtures, it can perform bending and tensile tests, and is mainly used for detecting bending strength of various arresters such as zinc oxide arresters, valve-type arresters, and tube-type arresters. The system uses closed-loop microcomputer control and features a wide and accurate load application speed and force measurement range, offering high precision and sensitivity in measuring and controlling load and displacement. This equipment complies with test standards including GB/T 11032-2016 "Metal Oxide Surge Arresters without Gaps for AC Systems," JB-T 8952-2018 "Polymer-Housed Metal Oxide Surge Arresters without Gaps for AC Systems," and GB 11032-2016 "Zinc Oxide Surge Arresters."

Technical Specifications
1. Maximum test force: 100 kN (adjustable)
2. Accuracy Class: Class 1
3. Structural form: Aluminum alloy outer frame
4. Test force indication allowable error limit: within ±1% of the indicated value
5. Load measurement range: 2% to 100% of full scale (FS)
6. Force resolution: 1/300000 of the maximum test force
7. Displacement display limit error: Within ±1% of the displayed value
8. Minimum displacement resolution: 0.01 mm
9. Crosshead speed adjustment range: 0.05~500 mm/min
10. Crosshead speed relative error: Within ±1% of the set value
11. Effective test width: 450mm (adjustable)
12. Effective stretching space distance: 650mm (adjustable)
13. Main unit dimensions: approximately 900*480*1950mm
14. Machine weight: approx. 250kg
15. Power supply: 220V, 0.75KW
16. Software and user interface: Software and interactive human-machine dialogue interface under the WINDOWS operating environment
17. The test process, as well as measurement, display, analysis, and control, are all completed by a microcomputer.
18. After the specimen is destroyed, the moving beam automatically stops (or returns to the initial position automatically).
19. Features programmable control and mechanical dual-limit protection
20. The machine will automatically shut down when the load exceeds the rated value by 3–5%.